Main menu:
Tools > Witschi Products
£
Combined Instrument for Quartz and Mechanical
Watches
This combined measurement and test instrument associates
all functions of test equipments for quartz watches and test
equipments for mechanical watches. It is the ideal test instrument
for the repair service, the lab and watch sales outlets.
Basic functions and measurement sequences, largely automated,
provide a fast and efficient operation.
Additional measurement modes provide a way to measure
watches with special escapements. The instrument, based on
the all-in-one concept, only requires a very small work area.
With its hi-res colour display, this top class instrument certainly
draws attention, also in the sales room.
General Description
A new technology provides extended test and measurement
facilities, allowing fast and professional troubleshooting
of quartz and mechanical watches.
Largely automated measurement sequences provided by
the instrument result in an unmatched user-friendliness. For
more advanced users, measurement parameters can also be
manually selected according to requirements. The main menu,
results, parameters, submenus and information are
presented on a colour display.
Testing Quartz Watches
Rate Measurement and Pulse Parameters
The analysis of the magnetic signal provides a display of the
accuracy. It also allows checking the period duration, the
pulse width as well as the inhibition period and the drive
level. Based on this information, it is possible to determine
the efficiency of a watch drive without opening the watch.
Rate and Consumption Measurement
The watch to be tested is supplied with a variable voltage.
Moveable probes are used as contact elements. The hands
can be observed during measurement by means of the
built-in mirror.
The instantaneous values of the rate deviation and of the
total consumption are displayed on a logarithmic scale. The
IC current, the period duration, the pulse width, the inhibition
period and the drive level are numerically displayed.
Pulse Analysis of the Motor Current
The current pulses are shown as a curve. The pulse shape is
an important criterion about the good operation of the
watch. Faults can be detected in the mechanical part of the
watch by comparing its measurements to those of a watch
of the same type in good condition. In addition, the pulse
width and the drive level are displayed numerically.
Testing Mechanical Watches
Diagram Display Mode
The diagram is continuously drawn. The numerical rate,
amplitude and beat measurements are displayed at the end
of the first measuring time. The average of the single measurements
is updated every 2 seconds, even with a longer
set measuring time.
Vario Display Mode
This mode provides a clear-cut assessment of the rate and
amplitude stability. The results are displayed in graphical
form on a logarithmic scale. The min., average and max.
values of single measurements since the beginning of the
measurement process are displayed under the current results.
The beat number as well as the measuring time since
the beginning of the measurement process are also displayed.
Trace Display Mode
In this mode, the measurement result of rate and amplitude
are recorded graphically in a time range depending on the
measuring time. It can be selected from 8 minutes to max.
64 hours. This provides a way to detect and locate recurring
deviations (e.g. faults in the gear train).
Position Display Mode
This mode provides measurement cycles with 2 to 6 test
positions by manually rotating the microphone. The instantaneous
measurements of rate, beat and amplitude are
collected during the measurement process. The average of
the rate and amplitude for each test position is displayed at
the end of the measurement cycle. The measured values of
the amplitudes are also represented by a light blue bar.
Technical Data
Measurement Possibilities
Rate deviation, current measurement, resistance measurement,
battery voltage, chopping level of motor pulse and rate measurement
of mechanical watches.
Rate Measurement
Measurement over the quartz frequency, signal sensing acoustical,
capacitive or over the supply current.
Measurement over the motor pulses, signal sensing magnetically
or over the supply voltage.
Measurement over the LCD-operating frequency.
Signal sources: Motor, quartz 32 kHz, LCD. Automatic changeover
between magnetic motor pulses and current pulses. Automatic
change-over between acoustical/capacitive quartz frequency
and quartz frequency over the current.
Measuring time: automatic definition over one motor period i.e.
inhibition period, min. 2 s, max. 120 s. Also manual setting: 2, 4,
10, 12, 20, 60, 120, 480 and 960 s.
Result display: measuring range ± 327 s/d, resolution 0.01 s/d.
Graphic display: measuring range -1 s to +10 s, logarithmic scale.
Display of the momentary value, independent of the selected
measuring time. Simultaneous display of the quartz accuracy for
watches with inhibition adjustment.
Status display: count down of the remaining measuring time. No
Signal in case of missing signal. Unstable and beep in case of an
unstable signal. Out of Range and beep if out of measuring range.
Module Supply
Mobile probes for direct contacting or by means of test leads with
probe tips.
Supply voltage: adjustable, 0 - 3.5 V, resolution 0.05 V.
Current Measurement
Instantaneous measurement of the IC current.
Integrated measurement of the total current over a measuring
period.
Measuring time: Automatic over a pulse period, min. 2 s,
max. 60 s.
Also manual setting.
Display total current: measuring range 20 mA, resolution 1 nA.
Display IC current: measuring range 10 ?A, resolution 1 nA.
Graphic display: momentary value of the total current, independent
of the selected measuring time. Display range 20 ?A, logarithmic
scale.
Error display: warning beep and over range display for current
>20mA.
Trace
Long time tracing of the rate and current measurement diagrams.
Time scale: automatic in accordance with the selected measuring
time; one pixel per measurement. Tracing length 6 min. to 50 h.
Resistance
Measurement of the coil resistance and detection of short circuits
and interruptions. Measuring range: 1 Ω - 10 MΩ, 3 digit display
with automatic range selector. Accuracy 1% of the measured value.
Error display: Short and warning beep for R<1 Ω.
Battery
Measurement of the battery voltage with loads of 2 MΩ (no Load)
and 2 kΩ (low Drain). Additional measurement with 100 Ω.
Pulse Generator
Test of stepping motor with programmable pulses.
Test of acoustic signal transmitters (buzzer).
Pulse width: programmable 2.94 - 31.25 ms in steps of
0.49 i.e. 0.98 ms.
Repetition frequency: programmable 1, 2, 8, 16 and 32 Hz.
Chopping level: programmable 37.5 - 100% in steps of 6.25%.
Voltage: programmable 0 to 3.5 V.
Buzzer test: bipolar square wave signal. Frequency 2kHz. Programmable
voltage from 0 up to 3.5 V peak.
Pulse Analysis
Stepping motor: the positive and negative pulses are alternately
displayed in the time scale of 8 or 16 ms.
Current scale: range 1 mA, logarithmic.
Numeric display: pulse width and chopping level.
Testing Mechanical Watches
Automatic selection of the beat number: 12000, 14400, 18000,
19800, 21600, 25200, 28800, 32400, 36000, 43200. Selectable
measuring time: 2, 4, 8, 20, 60, 120, 240, 480 and 960 s.
Range of the rate measurement: ± 300 s/d, resolution 0.1 s/d.
Graphic display of the rate: ± 50 s/d, logarithmic scale.
Amplitude: measuring range 80° to 360°. Lift angle adjustable
from 10° to 90°.
Beat error: measuring range 0 ms to 9.9 ms.
Measuring modes for watches with AP- and coaxial escapement.
Functions
Selectable languages: English, German and French.
Interfaces:
3 x RS232 for the connection of the Witschi thermo printer, of a PC
and of the Witschi GPS receiver.
DIN 8-pin for the connection of an external signal sensor.
Details
Time base: pre-aged, thermo-stabilised high frequency
quartz, OCXO.
Stability: ± 0.004 s/d between 10° and 50° C.
Aging for the first year: max. ± 0.03 s/d.
Casing: aluminium, glass and plastic.
Display: TFT colour graphic display, Ό VGA (320 x 240 dots) with
LED lighting.
Dimensions: 290 x 180 x 170 mm (w x h x d).
Weight: 3.8 kg microphone and mains adapter included.
Mains connection: mains adapter for 230 V~ or 120 V~, 1.2 A.
Accessories
Witschi thermo printer with universal- Item JB01-MCP7810
mains adapter, 90 V~ - 260 V~.
Thermo paper, roll. Item JB01-MM58-DPU20-N
Witschi GPS receiver for time base Item 19.91PK1
calibration or for the time base and
real time clock synchronisation.
AutoPrint: PC software for result and Item 64.55.901PK1
graphic file transmission to a PC.
Sub-Menu: